Gas Facilities DWG Detail for AutoCAD
This file shows the specifications and details that must be taken into account in the design of facilities for residential gas pressure regulation in 3 stages; according Colombian technical standards (NTC 2502, NTC 3631) .
Drawing labels, details, and other text information extracted from the CAD file (Translated from Spanish):
Connection with mm, Space for stamps, Contains:, design:, drawing:, flat, File: bengali.dwg, Space for stamps, Contains:, design:, drawing:, Date: february, Scale: indicated, flat, File: bengali.dwg, Insulating dielectric shirt, Fixing support detail for pipe perpendicular to the profile ceno, Detail of anchor band support for pipe, Anchoring pipe supports for use in the installation, Detail box, item, Fig. In de from eeppm, Measuring center posts, Detail of the laying of pipes in polyethylene, Distance for anchorage device, Fig., Ntc, Step heater, cover, gas pipe, Bypass tee, Conventions, Notes:, Detail measuring center without scale, Detail of first stage regulation without scale, polyethylene, elevator, General cutting valve, Universal flat seat, First stage regulator, valve, Second stage regulator, Registration valve, measurer, Cut valve, The gas supply system complies with the n.t.c. With the gas networks of eeppm companies. With the norms the accessories are against it with a product that meets the requirements of n.t.c. The constructor permanently installed the centers of the first stage regulator. As defined for networks the builder will not be able to start the gas networks until the respective one is approved, in case this is not an e.s.p. The right to provide the assistance said cabinets to accommodate meters be of the open type a direct with the exterior for the effects of gases of venting possible leaks that there are the horizontal vertical sections of the upright with hot galvanized ironworks that guarantee between the Network matrix support structure., The meter selected for each of the apartments the following specifications meter for natural gas of the type with a capacity up to in air for each of the apartments. Present was made on the premises for each gasodomestico with their respective outputs their respective power. Type of gas: natural qaptos: qt project: stratum of facilities: aptos will be used in first stage with the following specifications in the project bar entrance output to be used in second stage with the following specifications for each of the apartments bar Of output input to be used in third stage with the following specifications for each of the apartments bar entrance input, Equipment power kitchen the apartments type kw oven the apartments type kw heater the apartments type kw total power of the, Electrical rooms, Trash, cleanliness, elevator, hall, First stage regulator, circulation, Useful, Trash, cleanliness, elevator, hall, circulation, Useful, Kitchen, goal, Floor projection, elevator, hall, Terrace on floor, Room service, bedroom, master bedroom, living room, To dress, Terrace on floor, Room service, bedroom, master bedroom, living room, To dress, elevator, hall, Terrace on floor, Room service, bedroom, master bedroom, living room, To dress, Terrace on floor, Room service, bedroom, master bedroom, living room, To dress, elevator, hall, Room service, bedroom, master bedroom, living room, To dress, kitchen, Room service, bedroom, master bedroom, living room, To dress, kitchen, elevator, hall, Room service, bedroom, master bedroom, living room, To dress, Room service, bedroom, master bedroom, living room, To dress, Area clothing, kitchen, Area clothing, kitchen, Area clothing, kitchen, Area clothing, Typical floor plan, Ground floor plan, First floor scaled plant, via, access, platform, green area, South cl, Lower tv, Non-stop location, Ed. Bengali, Plants of all distribution networks of schemas details., Andrea cristina pungo, road, Places, Detail general non-stop cutting valve, polyethylene, elevator, General cutting valve, Variable length, Stretch: ground floor ground floor ground floor ground floor, Upright in carbon steel, Typical internal scale network, Date: february, Scale: indicated, Ed. Bengali, Plants of all distribution networks of schemas details., Andrea cristina pungo, suitable, Fit, suitable, Fit, Special ventilation, General cutting valve, Connection with mm, Sch, Sch, Andrea cristina pungo, Detail lattice ventilation fixed area gross area net, Applies for all apartments without scale, Projection duct for heater, Updated fc version, Measuring center, Point of consumption, Quick shut off valve, Pipe embedded in floor, Pipe embedded in wall, Conventions of izometrico plant, Pipe sight on wall, calculation memory, Isometric, Form for the inspection of internal facilities, plant, Isometric, scale, Local plant
Raw text data extracted from CAD file:
Language | Spanish |
Drawing Type | Detail |
Category | Mechanical, Electrical & Plumbing (MEP) |
Additional Screenshots | |
File Type | dwg |
Materials | Steel |
Measurement Units | |
Footprint Area | |
Building Features | Elevator, Car Parking Lot |
Tags | account, autocad, Design, DETAIL, details, DWG, einrichtungen, facilities, file, gas, gesundheit, l'approvisionnement en eau, la sant, le gaz, machine room, maquinas, maschinenrauminstallations, provision, residential, shows, specifications, wasser bestimmung, water |