Help on GoFundMe

ADVERTISEMENT

ADVERTISEMENT

Brisas Del Rio – Electrificacion DWG Block for AutoCAD

ELECTRIFICATION

Drawing labels, details, and other text information extracted from the CAD file (Translated from Spanish):

scale:, Neighborhood vista hemosa, Neighborhood cuatricentenaria, Barrio piñalidueña, Neighborhood villanueva, Barrio piñalidueña, Simon, pitch, Street, Sewage channel, Kva, Kva new, Kva, Sodium vapor lamps, Existing sodium vapor lamps., Sodium vapor lamps, Existing three-phase line of, Single-phase line of a.t. existing, Single-phase line in, Transformer of v., A.t. post existing, Light pole of a.t. mount, Light b.t. post mount, Heavy post from a.t. mount, B.t. heavy post mount, Terminal line of a.t. mount, Terminal line of a.t. B.t. existing, Wind of a.t. mount, B.t. wind mount, Wind of a.t. existing, B.t. wind existing, Existing single-phase line in, Tri-phase line of a.t. To make with arvidal, B.t. post existing, Wind of a.t. Relocated, B.t. wind Relocated, Tri-phase line of a.t. Kv, Heavy post from a.t. dismantle, B.t. heavy post dismantle, Terminal line of a.t. B.t. Underground, B.t. mount, Structure of a.t. mount, B.t. structure mount, Single-phase line of a.t. To make with arvidal, Single-phase line in underground workbench, Structure of a.t. existing, B.t. structure existing, Sodium vapor lamps, Heavy post from a.t. dismantle, B.t. heavy post dismantle, Trifasic line in new with quadruplex, Existing three-phase line in, Single-phase line of a.t. Kv., Trifasic underground line, Reflector halide metal, Concentric cable, B.t. hex post From mts, Colonial mts post for luminaires, New transformers will be fed in the phases of the circuit of high voltage coming from bolivia city with their respective protections a grounding system in high tension. The high voltage conductor will make the arvidal # awg. Aluminum the low voltage is the arvidal # awg. aluminum. All new high-pressure sodium wattage luminaires of volt watts are to be installed with cable # thhn copper underground lighting will be done by bench, East, points, north, DC. River breezes, scale:, sheet:, content:, Indicated, date:, Electrification improvement, series:, March, Relative location:, city, Barinas, C.i.v., topography:, C.i.v., drawing:, civil engineer:, C.g.s.h., electrical engineer:, Ing. Juan C. Rangel, designer:, draft:, owner:, Community council breezes r.l. Rif:, Ing. Ramon fermin, Juan carlos rangel garcias, C.i.v., Silvio uzcategui, Project of electrical improvement in high low tension with public lighting in the neighborhood antonio jose de sucre in city municipality. Barinas, Antonio jose de sucre, scale:, Descriptive legend, Bolivia city circuit ii of existing, Concrete type mts of solid concrete.

Raw text data extracted from CAD file:

Drawing labels, details, and other text information extracted from the CAD file (Translated from Spanish):

scale:, Neighborhood vista hemosa, Neighborhood cuatricentenaria, Neighborhood piñalidueña, Neighborhood villanueva, Neighborhood piñalidueña, Simonsito, pitch, Street, Sewage channel, Kva, Kva new, Kva, Sodium vapor lamps, Existing sodium vapor lamps., Sodium vapor lamps, Existing three-phase line of, Single-phase line of a.t. existing, Single-phase line in, Transformer of v., A.t. post existing, Light pole of a.t. mount, Light b.t. post mount, Heavy post from a.t. mount, B.t. heavy post mount, Terminal line of a.t. mount, Terminal line of a.t. B.t. existing, Wind from a.t. mount, B.t. wind mount, Wind from a.t. existing, B.t. wind existing, Existing single-phase line in, Tri-phase line of a.t. To make with arvidal, B.t. post existing, Wind from a.t. Relocated, B.t. wind Relocated, Tri-phase line of a.t. Kv, Heavy post from a.t. dismantle, B.t. heavy post dismantle, Terminal line of a.t. B.t. Underground, B.t. terminal line mount, A.t. structure mount, B.t. structure mount, Single-phase line of a.t. To make with arvidal, Single-phase line in underground bench, A.t. structure existing, B.t. structure existing, Sodium vapor lamps from, Heavy post from a.t. dismantle, B.t. heavy post dismantle, Trifasic line in new with quadruplex, Existing three-phase line in, Single-phase line of a.t. Kv., Trifasic underground line, Reflector halide metal, Concentric cable, B.t. hex post From mts, Colonial mts post for luminaires, New transformers will be fed in the phases of the circuit of high voltage coming from bolivia city with their respective protections a grounding system in high voltage. The high voltage conductor will make the # awg arvidal. Aluminum the low voltage is the arvidal # awg. aluminum. All new high pressure sodium wattage luminaires of volt watts will be installed with cable # thhn copper underground lighting will be done by bench, East, points, north, DC. River breezes, scale:, sheet:, content:, Indicated, date:, Electrification improvement, series:, March, Relative location:, city, Barinas, C.i.v., topography:, C.i.v., drawing:, civil engineer:, C.g.s.h., electrical engineer:, Ing. Juan C. Rangel, designer:, draft:, owner:, Community council breezes r.l. Rif:, Ing. Ramon fermin, Juan carlos rangel garcias, C.i.v., Silvio uzcategui, Project of electrical improvement in high low tension with public lighting in the neighborhood antonio jose de sucre in city municipality. Barinas, Antonio jose de sucre, scale:, Descriptive legend, Bolivia city circuit ii of existing, Concrete type mts of solid concrete.

Raw text data extracted from CAD file:

Language Spanish
Drawing Type Block
Category
Additional Screenshots
File Type dwg
Materials Aluminum, Concrete, Other
Measurement Units
Footprint Area
Building Features Car Parking Lot
Tags , , , , , , , , , , , , , , , , , , , , , , ,

ADVERTISEMENT

CAD Drawings

Leave a Reply