Condominium Horizontal DWG Plan for AutoCAD
16 Properties of 2 levels; amenities; TULA area; HGO. Mexico. Full Architectural Plans
Drawing labels, details, and other text information extracted from the CAD file (Translated from Spanish):
ground floor, first floor, dining room, room, kitchen, laundry, sanitary, corridor, access, pedestrian, bedroom jr, master bedroom, bathroom, dressing room, lobby, terrace, town of tula, state of hidalgo, mexico, san pedro alpuyeca , address :, no.deproject, project key, drawing :, dimension :, dimension, date, date :, graphic scale, scale :, drawing no., north, location, general notes :, cutting direction, symbology, access main, change of level, level of finished floor, owner :, acg, seals, director responsible for work :, structural design :, design facilities :, architectural design :, revisions :, cxf, cut by facade, table of housing areas, local, laundry area, lobby and circulations, total built, arq. guillermo absalón castro, s i a p s a, ing. pedro wells jimenez, breakfast bar, roof plant, tula – tepeji highway, el cielito road, development of infrastructure and work, d m i n i s t r a c i o n d o b a r, ing. richard reyes bouchan, c o i n p r o s c, c o n s u l t o r e s i n g e n e a n d e r e a n d e c t o n s, resident of work:, ing. cesar cruz gonzalez, project design and supervision, arq. guillermo absalón castro, front facade, front left, back facade, front der., court d-d ‘, court b-b’, court c-c ‘, court a-a’, mrs., arq., reg. dro no:, pre-cast concrete step, apparent finish, integral color to choose, topsoil filling, compacted tepetate filling, marble base, set of keys with mixer, marble plate, seated with glue-marmol, annealed red partition wall , against chromium of cespol, wall of red partition annealed or tabicon, marble skirt, seated with gluemarmol, electrical simbologia, distribution board, simple damper, meter and switch of knives, three-way switch or ladder, pipeline drowned poly-pipe , duct pipeline drowned in floor or wall, diagram unifilar housing type, circuit, switch, goes, total, measuring equipment, internal rush, square’d, a, b, d, e, low, rise, n, r , p, q, phases, concept, int. of blades, meter, quantity, unit, pza, duplex contact, three-phase contact, socket, output, contact in room, dampers, flying buttresses, board, height, materials, guiamec á nica, npt, dining room and bedrooms, contact in patio , service and kitchen, hydraulic simbología, copper pipe, diam. indicated, heater, low column of cold water, rises column of cold water, b.c.a.f., s.c.a.f., tee, diam. indicated, air jug, float, and connection to heater, washbasin, household outlet, washing machines, laundry, sink, shower, isometric, a new observation and accept the network properly tested., After this observation will download the lines and immediately will reload in the same conditions listed above, to carry out, manometric proceeding to correct the flaws detected., in case of observing a variation in the readings of the manometers will proceed to the revision of the lines and determine the causes of the variation In the readings, logical points of section or network to be tested., according to the development of the network, it may be fully tested or choose sections of it with the condition of being able to subsequently verify the conditions of,: all the networks of Cold water and hot water feeds should be tested under the following conditions :, normally used in bronze connections standard for water conduction., diameters specified in the project., hydraulic materials, to remove the burned gases outside the room. the chimney pipe must have, at least the same diameter of the pipe, a chimney, installation data, angular key, coflex hose, female plug, globe key, furniture, washbasins, watering can, chives sprinkler, separation, wall , distance between, pipelines, gac, health simbology, notes: the sewage drops will be from pvc, the rainwater drops will be from pvc, the connections will be lowered to registers will be, the network of connections to seran registers, the entire network interior will be pvc ,, according to the indicated diameter, pvc with the slope, indicated diameters, pvc ,, cement asbestos diam. indicated, pvc tube, indicated diameter, black water drop, ban, rear exit, parapet strainer, connection to junction, width, diameter, thickness, esp. of ridge, dimensions of stock, filling of, tepetate, bed of, tezontle, compacted, to slope and length of the section., to be placed below the level of the hydraulic pipes, note :, or sanitary., polished thickness of, flattened finish , level of land, variable, hermetica without strainer, concrete cover, red annealed, wall of partition, concrete template, discharge to drainage, to reach level, filling of tezontle, firm of concrete,
Raw text data extracted from CAD file:
Language | Spanish |
Drawing Type | Plan |
Category | House |
Additional Screenshots |
|
File Type | dwg |
Materials | Concrete, Other |
Measurement Units | Metric |
Footprint Area | |
Building Features | Deck / Patio |
Tags | amenities, apartamento, apartment, appartement, architectural, area, aufenthalt, autocad, casa, chalet, condominium, dwelling unit, DWG, Family, full, haus, horizontal, house, Housing, levels, logement, maison, mexico, plan, properties, residên, residence, unidade de moradia, villa, wohnung, wohnung einheit |