Electrical Plans Semefo Tapachula DWG Plan for AutoCAD

ADVERTISEMENT

ADVERTISEMENT

or

ELECTRIC PLANS INSTALLATION WORK SEMEFO TAPACHULA

Drawing labels, details, and other text information extracted from the CAD file (Translated from Galician):

n.p.t., n.p.t, n.p.t., n.p.t, n.p.t., n.p.t., bench, main substation, detail of electrical installation at the junction, cabinet of, driver of the, electrode of, grounded, copperwejd rod, for rush, earth electrode, substation, int main, neutral feeder conductor, b.t.a., rush, conductor of ground equipment, phase, neutral, naked, meters, naked, normal contact, ivory color, detail, active driver, phase, laying conductor, naked earth, Equivalent leviton brand approved, land catalog, color nylon plate, Dual-pole duplex monophasic contact, capacity with take-off, neutral ground, driver put, capacity of threads in piping, diameter, threads, capacity, location sketch, digitize:, scale:, plane:, date:, January of, Low voltage network lighting contacts, location sketch, machine room, incinerator, infectology, empty, necropcia, cellar, files, reports, acknowledgments, legal doctor, laboratory, rays, wash, access, sanitary, secretary, parking lot, ambulance patrol access, direction, access, waiting room, sanitary, garden, tapachula, huixtla, highway, Fluorescent lamp type superimposed, incandescent weatherproof whip, normal duplex monophasic contact, simple shutter, lighting board, thermomagnetic switch, lamp, thermomagnetic switch, basis for measurement cfe, earth system, pipe by floor wall for contacts, porcelain pipe for luminaires, cabling nomenclature, the pipe to use in inner coating will be of tube conduit thin wall of mm the pipe to use in polarized contacts will be of tube thin wall of the pipe for external lighting will be of pvc conduit heavy of the pipe for the main feeding will be of pvc conduit of all the Electrical paths of this plane are schematic can be changed in the field by the supevisor if this is required. All boards will be placed measured from top. the color code for the insulation of the conductors will be the following: active conductors with different colors for each that are not green gray. Gray neutral neutral conductor. green color isolated conductor. conductor of naked physical earth. For calibers where it is not possible to comply with the colors, the points with the corresponding colors for all the metal parts are labeled that in normal conditions of non-carrying year of must be connected system of lands. the insulation of the conductors will be antillama. In any case, the voltage drop of the supply circuits must be exceeded, according to the mandate of the Mexican official standard, the voltage supply circuit circuit breaker contacts must be installed for ground fault in all where liquid contact moisture exists. These are garages in applications the outdoors Height of the shut-offs will be of mts except if indicated otherwise. The mounting height of the contacts is indicated in the symbols. This plan complies with the Mexican official standard to use this plan exclusively for electrical installation., exit for refresh sand compressor

Raw text data extracted from CAD file:

Language N/A
Drawing Type Plan
Category
Additional Screenshots
File Type dwg
Materials Other
Measurement Units
Footprint Area
Building Features Garage, Car Parking Lot, Garden / Park
Tags , , , , , , , , , , , , , , , , , ,
or
ADVERTISEMENT

Release Information

Share Your Valuable Opinions

Cart (0)

  • Your cart is empty.