ADVERTISEMENT

ADVERTISEMENT

Gas Project DWG Full Project for AutoCAD

Gas project for house building social housing; with construction details and calculation for admission to a regulatory agency.

Drawing labels, details, and other text information extracted from the CAD file (Translated from Spanish):

note., Excavation equipment, Yellow ribbon, With legend, Poor concrete brick, sand, pipeline, Dimensions in millimeters, For pipes consider the outside diameter, The drawing is only illustrative, R.g., According to art., Gross minimum volume, Total power, Pt kw, Type gas appliance except stoves., Volume of enclosures depending on the power of the, Pt kw, Pt: total power expressed in kilowatt corresponding to the sum of the nominal powers of the type gas appliances installed in an enclosure., Pm: numerical value of pt effects of calculation of minimum gross volume., Real vr min, Isometric scheme, R.g., Cm., Safety warning vents, According to art., For its protection do not cover this ventilation. Breach of this provision compromises the health and safety of consumers., Cm., Requirements safety warnings, According to art., R.g., The signage must be made by means of metal plates of rigid plastic inscription another similar system that must according to the following requirements: the stickers must be permanent made in paper of high class according to established in the official Chilean standard the dimensions must be the appropriate ones The format of the letter of such a size as to allow its normal reading a distance of mts. Of a color that protrudes from the bottom of these. The painting must be carried out with paints whose characteristics ensure that environmental conditions are not removed in the normal cleaning process. The system of subjection of the plaque plate should be either screwed welded another of similar characteristics. The location of the inscription system selected should be in a place so that the people’s eyes are left., Dimensions in, Installation detail, kitchen, Bell, kitchen, Plug, Liquefied petroleum gas meters, Safety warnings, No smoking to light fire., Exclusive enclosure for gas meters., Make sure that the meter valve you, Which corresponds to it., Do not open a meter valve without making sure the, Of the rest of the installation of the other meters, Are closed., In case of closing a meter valve, Do not open it again without checking, The rest of the valves of the installation, Are closed., Emergency phone: gas that supplies the, Cm., Safety warning meters, According to art., Inside the, Cm., wind, Gases, Gases, wind, Cap detail, Vacuum cleaner cap, stationary, wind, seal, Protection case, For gas piping, gas pipe, partition, any element, dividing, gas, According to a decree law, The installation of gas pipes inside buildings, To make the view in recessed ducts in slab, Radier The following should be considered:, The installation of gas pipes should not cause tensions, Structural features in building components that exceed, Design limits allowed., The sight gas pipes shall be secured to the wall, wall., Other intervention in structural elements of the, Building to perform a must be previously, In a report by a calculating engineer., The built-in slab pipes must have, Protection by means of a coating, Must carry out in exclusive areas with elements suitable for, Allow the identification of its route. These areas will extend, No more than the parallel walls of the respective, pipelines. For the case where the laying of pipes is carried out in, This area can be extended to, Joints must be protected with a polystyrene insulation, Expanded one of similar characteristics, Outer diameter of the gas pipe., With an inner diameter of at least mm. to the, Steel sheath of non-flame propagating plastic material, Walls divisions can be used, The case of pipes that cross perpendicularly, Any possible gas leakage to the outside., The other is sealed in such a way as to prevent, Of good with one end in such conditions, Hidden penetration of uprights, Extending to at least cm. Beyond the, Wall partition hollow of the enclosure in which it is, Shall communicate with the outside of the, Way to avoid galvanic corrosion., Metal structures of the nor with others, So that you are not in contact with the, By means of securing elements., Watertight in all its suitably fixed, Be in one piece continuous section, Compatible with the material of the gas pipe., Other material of similar mechanical resistance, To be with, To cross, Sheath detail, Gas pipes should remain at cm. in, Any sense of intersection with pipes of other services., All crosses protected with a concrete layer of concrete, Cm. The separation of the pipe from, Of gas of such length., The crosses

Raw text data extracted from CAD file:

Language Spanish
Drawing Type Full Project
Category
Additional Screenshots
File Type dwg
Materials Concrete, Plastic, Steel, Other
Measurement Units
Footprint Area
Building Features Deck / Patio, Car Parking Lot
Tags , , , , , , , , , , , , , , , , , , , , , , ,

ADVERTISEMENT

Leave a Reply

ADVERTISEMENT