Industrial Building – Gas Project DWG Full Project for AutoCAD
Industrial Building – Gas Project – Plants – Sectiond – Details
Drawing labels, details, and other text information extracted from the CAD file (Translated from Spanish):
abutment, slope, cp, slope min., cyclonic mesh, concrete ramps, rev .: industrial, real estate, engineering, rev., femsa, industrial building, industrial building, global mechanical, production, area, production, towards, area from, up, top, boards, up to, filter, filter, new, existing, compressor, dryer, new, sleeve, pipe, existing, ingersoll rand, compressor, dryer, zeks, ebm, tank, air, tank, oil water, separator, separator, pipe, future, future, preparation to future, installation of intelliflow, by owner, intelliflow by the owner, for installation, future preparation, future, construction and service, air tank, air, dry , water – oil, separator, without scale, not scale, isometric of compressors, dreen, discharge, valve, flexible, metal, hose, detail of flexible connection, drain, flex, steel hose, valve, flex connection detail, discharge , air compressor, description, ingersoll rand compressed air filters, new equipmen t :, existing equipment :, prime finish, refrigerated air dryer ingersoll-rand, ingersoll rand air dryer, ingersoll rand air compressor, contractor, all the equipment will be, supplied by the compressor room, suppiler by owner, note :, all equipment shall be, specifications, grooved or threaded, provide adequate support, manufacturing area, specs, proper pipe hangers, grooved or screwed fittings, valves and accessories. provide, general notes, hanger, eye rod, pipe ring, threaded at end, steel, all thread, flat washer, ring hanger, adjustable, rod, sidewinder, sammy, manufacturer, or similar, location plan, support details, -rod and ring, tolco, c-clamp, rod and ring, retaining, strap, adjustable ring hanger, threaded side beam bracket, all thread rod, bolt and nut, adjustable ring, beam clamp, lock, nut req’d, view aa, u-bolt, saddle, pipe stand, angle clip, pipe support, angle clip, rod and ring, light duty, steel bracket, per nfpa, or angle, trapeze pipe, trapeze hanger, or bolted, special hanger, point for welded, maximum distance between supports according to table included in this plan., all fasteners must comply with the table shown in plan., clamps for beams should be used where the pipe is, suspended from the steel structure, should be select according to, in general, the pipe should be supported by walls, beams, columns and slabs, using adequate structure in situations where it can not be supported, load to support, and configuration., the structure should receive a pre-approval to the installation., Threaded when attached to endless type support plates, should be used for keep the position on the beam, that is required., support with endless should have threaded ends, use nuts, safety on the top. no cables, chains, belts, fastening sheets are to be used on supports located on beams., use supports shown in attached figures, according to their conditions., If it is necessary to use another type of fix, it must be submitted to Revisio., not to support the pipe of other pipes, ducts or equipment, that are not part of the structure of the building, supports with cable, belts, or supports to metal structure not suitable., the following supports will not be accepted or allowed :, provide lateral and horizontal anti-earthquake support in each, change of direction in main head, compressor room, maximum distance between hangers, copper tube, threaded lightwall, steel pipe, cpvc, nominal pipe, steel pipe except, are allowed. ,, change of direction at air loop and crossmains, the following are not acceptable or permitted: wire hangers, perforated straps, or hanging, equipment which is not building structure., do not support piping from or ther pipes, ductwork or other, from unreinforced metal roof deck., support conditions., if need use other figure, the arrangement, use figures shown in this sheet, in accordance with the, shall be submitted to revision., retaining straps shall be used in hangers pipe located in beams, attachments and hangers. no wire, chain or perforated straps, rods of circular cross section. use adjusting locknuts at upper, hanger rods shall be threaded both ends, or continuous threaded, maintain the position on the beam where required. ,, flange of structural shapes. retaining straps shall be used to, c-clamps shall be used when attaching to hanger rod to the top, must receive approval prior to installation, alternative attachments or substructure assemblies, in situations where approved attachments can not be used, load to be suported, and load configuration., columns and slabs using approved structural attachments, c-clamp shall have locknuts and cup point set screws. top, in general, piping system shall be supported from walls, beams, building steel, clamp style shall be selected on the basis of, beam clamps shall be
Raw text data extracted from CAD file:
Language | Spanish |
Drawing Type | Full Project |
Category | Mechanical, Electrical & Plumbing (MEP) |
Additional Screenshots |
|
File Type | dwg |
Materials | Concrete, Plastic, Steel, Other, N/A |
Measurement Units | Metric |
Footprint Area | |
Building Features | Deck / Patio |
Tags | autocad, building, details, DWG, einrichtungen, facilities, full, gas, gesundheit, industrial, l'approvisionnement en eau, la sant, le gaz, machine room, maquinas, maschinenrauminstallations, plants, Project, provision, wasser bestimmung, water |