ADVERTISEMENT

ADVERTISEMENT

Lubricanter Center DWG Section for AutoCAD

Complete planes of lubricanter center – Sections – Elevations – Details – Structures plants – Roofs

Drawing labels, details, and other text information extracted from the CAD file (Translated from Spanish):

j.a.p.s., office, workshop area, tire change area, work area, oil change area, ladies, gentlemen, employees, pool, tank, septic, enters drinking water, oils, collector, v. crown, v. tapichel, scale:, detail of beams, detail of plates and isolated columns, n.terreno, platina, profiles of steel, profile, thickness, inch, section, welding, structural steel, notes for metal structure, size of the electrode, size of the profile, amperage, all measurements will be verified on the site before proceeding to the manufacture of the structures, according to the geometries given in the plans. Any doubt in the interpretation of the plans should be evacuated in advance with the professional inspector of the work, parts that in the opinion of the inspector are deficient in their quality of manufacture and assembly, will not be accepted., the contractor will supply all those accessories not expressly indicated in drawings but that are necessary for a correct placement of the metallic structure., complementary accessories , verification of measures, irrigation key., thn, buoy type valve, water meter, bn, coffee, retention valve., flexible union., valv Floor type retention with built-in pascon, connection of potable or hot water to furniture, drainage of floor with siphon, with indicated d and grille lid in polished bronze., cold water column with dy number indicated, pump, number indicated., Valve of damper, downpipe., hydropneumatic tank., floor register for sewage, with polished bronze lid indoors or plugs, unloading of sanitary furniture or similar in floor or wall with indicated d., mechanical symbology, pvc threading in exteriors ., record for black water in sky., snpt, cv-n, ban-n, on level of finished floor, cover structural sheet, a gutter, downpipe hg, square profile, liquid level, concrete lightened, variable, angular frame of, red minio, cover with angular, structural element, hoop, longitudinal steel, poor concrete seal, firm ground, ground, connect to collector, plant, concrete cover, pvc pipe, area, oil change, workshop, change of tires, warehouses, cover lam ina, structural, pedestal, concrete, ground level, wall, containment, nailed in rt, lightweight wall, block wall, retention, you should leave at least an access to the ceiling, the pipe floors and mezzanines should be dried and cleaned before, the electrical conductors must carry visible marks of the factory, every outlet on the wall shall carry metal box., the maximum depth of the outer edge of the wall boxes shall be, all metal box shall be attached to the pipe by means of of connectors, the meter should be accessible for reading and also, the electrical installation should go in pipes, use boxes of record, and where it is installed should be in register with t., the ground rod should be outside the construction, the metal boxes of boards and switches must, the joints will only be accepted in register boxes with a minimum, with cover and connectors, curves, unions and galvanized gauze to hold, electric notes :, the installation of the conductors., of ths layers of insulating tape., the pipe., to be protected against the rain., to be solidly landed., electrical symbols, exit for bell, current input breaker box, thermo-magnetic distribution board, special kitchen outlet and thermocouple, incandescent lamp output, double outlet, wired switch lamp, wiring for outlets, outlet for reflectors, single or multiple damper, wiring for lamps, TV antenna output, telephone output, kwh meter, amps, gauge, conductor, busbars, total potential, estimated demand, total, amp, consumption, description, circuit, voltage, with additional ground bar to neutral bar., power, protection, type, breaker, total current, conduit, thhn, phase, board a, free, sockets, special outlet, lights, to the surface of the land, to facilitate, longitudinal section, septic tank plant, septic tank, no scale, entrance, level liq uido, lid, its location and tank cleaning., concrete floor, armor., brick to teson and, shows on the floor or, with columns as is, the walls will be, exit, column drilled on site, prolong the covers in the form of a register box, when you want to leave the tank buried ,, note:, main switch, connected to the neutral, ground rod, single line diagram, flashing, type conduit, tails, distribution box, to san pedro, a santa maría, a san marcos, approval review commission, building permits, project :, lubricentro, property of :, province, san jose, tarrazu, canton, san marcos, district, drawing :, fas, responsible professional, signature: , professional responsible technical direction, responsible professional execution, information r

Raw text data extracted from CAD file:

Language Spanish
Drawing Type Section
Category
Additional Screenshots
File Type dwg
Materials Concrete, Steel, Other
Measurement Units Metric
Footprint Area
Building Features Pool
Tags , , , , , , , , , , , , , , ,

ADVERTISEMENT

CAD Projects

Leave a Reply

ADVERTISEMENT