Help on GoFundMe

ADVERTISEMENT

ADVERTISEMENT

Substation Pedestal Type DWG Detail for AutoCAD

Detail of substation pedestal type with aerial assault – Include emergency plant – Lighting – Main boards system of land distribution and unfiled diagram

Drawing labels, details, and other text information extracted from the CAD file (Translated from Spanish):

axis, E.g., Tab., Transfer, N.p.t., Stuffing material, Compacted to min., concrete, Pvc pipe mm, tube of, Between axes of substation, N.p.t., Stuffing material, Compacted to min., concrete, Pvc pipe mm, Compacted floor min., Reservation., Detail, tension, Duct bank for medium, Shot without affecting other cables leaving a duct, Against mechanical damage its, Application to place a three-wire circuit, Kv. Protecting the cables between each other, Substation, Future growth, Check civil work with clf, Electrical connection volts load installed load requested kva, Note: The equipment must be grounded by means of a soldering wire. The cable must be installed in its chassis cabinet. The access door must be of the cyclonic mesh type to allow the free passage of the air from the emergency plant. The gate must be connected to the ground. A record for testing measurements on the rod electrode that is located at the center of the substation room, Duplex contact polarized earth mca. Leviton white color no. Mounted on wall. Connected normal system., Eraser single mark royer mod. Siena with plaque stand, Luminaire bulb type magg model street lamp with energy saving lamp of lfc watts volts hertz., Substation three-phase distribution transformer pedestal type three-phase distribution transformer pedestal type front radial operation type of cooling in oil manufactured under ansi standards designed built to operate m.s.n.m. Primary voltages: with four standard draws of the voltage connection with removable bayonet type fuse nozzles from the inside. Secondary voltages: connection characteristics accessories according to standards. Manufactured to operate with a temperature of about an average of a maximum of capacities: kva. According to the commercial data provided by the manufacturer the recommended equipment is the following brand prolec capacity kva phases cooling or environment primary voltage volts secondary voltage volts connection frequency hertz elevation of type of business industry height snm mexicali baja california north conditions clean dimensions mts, Substation three-phase distribution transformer pedestal type three-phase distribution transformer pedestal type front radial operation type of cooling in oil manufactured under ansi standards designed built to operate m.s.n.m. Primary voltages: with four standard draws of the voltage connection with removable bayonet type fuse nozzles from the inside. Secondary voltages: connection characteristics accessories according to standards. Manufactured to operate with a temperature of about an average of a maximum of capacities: kva. According to the commercial data provided by the manufacturer the recommended equipment is the following brand prolec capacity kva phases cooling or to environment primary voltage volts secondary voltage volts connection starter frequency hertz elevation of type of business industry height snm mexicali baja california north conditions clean dimensions mts, Emergency plant installed level of floor without acoustic box model capacity continuous service kva capacity service emergency kva specifications in f.p. Voltage volts continuous capacity up to msnm emergency capacity up to msnm control vdc frequency hz number of phases number of threads automatic start time to position full load in automatic units seg. Voltage regulation frequency regulation engine brand cummins model maximum effective power hp continuous effective power hp number of cylinders placement of cylinders in-line aspiration turbocharged diesel fuel consumption fuel full load generator brand newage stamford model number of poles accessories capacity fuel tank batteries cables Of batteries base of batteries silencer pza flexible tube pza cushions dimensions long cms width cms high, Emergency plant with fuel tank integrated in the with transfer equipment automatic control, Octagonal pole hollow to center specification notes: reinforced concrete material designation key: concrete length resistance slope round section will also be hollow specified strength will be the minimum breaking load will be applied from the tip, Finished floor level, In one of the passes to the center of the axis with direction of the diameter of, Octagonal concrete pole of length with structure for medium tension with disconnecting blade type insulation class for class nbai in vertical mounting with vertical opening verifying with, Live line connector, Cable polycon xlpe type gauge level amps load capacity three conductors in a single pipe of filling factor temperature factor approximate length of equipment

Raw text data extracted from CAD file:

Language Spanish
Drawing Type Detail
Category
Additional Screenshots
File Type dwg
Materials Concrete, Other
Measurement Units
Footprint Area
Building Features Car Parking Lot
Tags , , , , , , , , , , , , , , , , , , , , , , ,

ADVERTISEMENT

Leave a Reply

ADVERTISEMENT