Installation Of Lightning And Construction Details; Installation And Quantification Of Materials DWG Full Project for AutoCAD

ADVERTISEMENT

ADVERTISEMENT

or

Installation Project Lightning rod for tire recycler Industry; has construction details; Installation process; symbolism; quantification of materials; the radius of protection to manually

Drawing labels, details, and other text information extracted from the CAD file (Translated from Spanish):

Meters, Intermediate protection mts mts., Recreational area, Pedestrian walker, Bicycling, parking lot, pending, service yard, N.p.t, Meters, access, N.p.t, Meters, Meters, Intermediate protection mts mts., Base detail for telescopic mast, Telescopic stainless steel mast, Copper wire, Detail of well for rehilete, Mts, Gap mix, Compacted soil, Mts., ditch., Level of floor., Mts., Mechanical type connector, Detail for landing of delta in rehiletes, Copper wire, Mts., Rehilete, Concrete lining detail, Concrete lining, Structural reinforcement for mast base, Prevectron tip detail, Lightning protection, Standard protection mts mts., localization map., observations, The land is in an area has the necessary conditions for the construction of the recycling industry building, Plan key:, Dimension:, revised:, scale:, date:, draft:, flat:, Flat installation lightning rod, Meters, lighting rod, Prevectron tip, Stainless steel mast. base, Pipe connector, Mechanical connector, Wall switch connector, Ground switch, Copper wire of mm., All conductors to be installed in the physical ground system will be of the color type except those that come from the ground electrodes that will be of the naked type of cobresemiduro the terrain where the chemical electrode will be placed will be by iron chip chemical compound marks due to the characteristics So that the system gives us a minimum value. Copper rods will be installed in electrolytic copper all the connections between conductors bars will be through compression termnales of double barrel long bronze screws to the connections between cables equipment racks will be of lasmismas characteristics but with iron screws in both cases it will be applied in The contact surfaces a compound to ensure electrical conductivity., Specifications for construction installation, Intermediate protection mts mts., Ground clamp, Prevectron tip, Stainless steel mast. base, Pipe connector, Mechanical connector, Wall switch connector, Ground switch, Copper wire of mm., Ground clamp, N.p.t, Lightning protection, Isometric, Galvanized steel gauge cover, Lightning protection, Symbology:, Acot:, revised:, scale:, date:, draft:, Eco recycling rim industry, flat:, Plane lightning rod installation, graphic scale:, Notes of the plane:, observations:, Meters, revised:, localization map:, Terrain data:, The land is in an area has the necessary conditions for the construction of the recycling industry building, key, lighting rod, Recreational area, Playground trailers feet, Bay waiting trailer, Pedestrian walker, Bicycling, parking lot, pending, service yard, N.p.t, Meters, access, N.p.t, Meters, Intermediate protection mts mts., Radius of protection in the pre-ray lightning protection, Symbology:, Acot:, revised:, scale:, date:, draft:, Eco recycling rim industry, flat:, Plane lightning rod installation, graphic scale:, Notes of the plane:, observations:, Meters, revised:, localization map:, Terrain data:, The land is in an area has the necessary conditions for the construction of the recycling industry building, key, Surface area permeable area production area management area dining room warehouse storage of raw material, Base detail for telescopic mast, Telescopic stainless steel mast, Copper wire, Detail of well for rehilete, Mts, Gap mix, Compacted soil, Mts., ditch., Level of floor., Mts., Mechanical type connector, Detail for landing of delta in rehiletes, Copper wire, Mts., Rehilete, Concrete lining detail, Concrete lining, Structural reinforcement for mast base, Prevectron tip detail, Lightning protection, Standard protection mts mts., Intermediate protection mts mts., All conductors to be installed in the physical ground system will be of the color type except those that come from the ground electrodes that will be of the naked type of cobresemiduro the terrain where the chemical electrode will be placed will be by iron chip chemical compound marks due to the characteristics So that the system gives us a minimum value. Copper rods will be installed in electrolytic copper all the connections between conductors bars will be through compression termnales of double barrel long bronze screws to the connections between cables equipment racks will be of lasmismas characteristics but with iron screws in both cases it will be applied in The contact surfaces a compound to ensure electrical conductivity

Raw text data extracted from CAD file:

Language Spanish
Drawing Type Full Project
Category
Additional Screenshots Missing Attachment
File Type dwg
Materials Concrete, Steel
Measurement Units
Footprint Area
Building Features Deck / Patio, Car Parking Lot, Garden / Park
Tags , , , , , , , , , , , , , , , , , , , , , , , , , ,