Several Details Of Electricity In Low And Medium Voltage DWG Detail for AutoCAD
Several details of Electricity in Low and Medium Voltage. Poles transition from medium to low voltage is included; Installation detail Transformer Pad Mounted type; Electricity Basement detail; Details of Poles.
Drawing labels, details, and other text information extracted from the CAD file (Translated from Spanish):
Only one per phase of the distribution type will be used., Tribution of each, To provide some service., Detail transition structure, The land drain will be made inside the post. In addition, another downpipe can be installed inside the one in which case the, The lightning rods for an underground system are of type two per phase of the distribution type. For underground connections, Next to the post you must build a tanquilla of m. On the floor of the same must leave an area with gravel to, sewer system. The floor of the log must have a slope to the drain. For more details, consult, In the transition you must install protective equipment in addition to lightning protection for overvoltage protection., Is called transition to the change of conductor bare air isolated conductor to interconnect with a system of underground distribution, Ground must be installed inside the log in the area for drainage. Connect the earth tube., Connector stirrup for arvidal, Awg kv power cable with display, Tubular foot post. simple, insulator, Down, Spike awg kv mca. Cat. do not., Awg semi-hard wire., Kv fuse cutouts, Autovalvular pararrayo zinc oxide kv mca. Joslyn, Galvanized metal crosspiece, Copperweld mca. Copperweld., Copperweld rod connector., Material transition, rush, To the transformer, C.f.e., Pvc, A: terna with only elementary school, Copper bare lime cable., Awg kv spike insulation, Kv autovalvular arrest, Kv fuse cut-off switch, Cup ternimal spike lime. Awg kv, Galvanized iron crosshead, Cable xple cal., Connection to the stirrup, Arg downs, B: bench top, C: air transition with single primary line, E: base for underground air pole, F: philips type, Locking butterfly with pressure washer stainless steel nut, Channel stainless steel unistrut, Stainless steel wall mount for heavy type tray, Stainless steel omega ceiling mount, Stainless steel ceiling mount for heavy type tray, Heavy-duty fiberglass ladder type tray, Stainless steel fixing nut with washer nut, Stainless steel threaded rod, Stainless steel nut, Pressure washer, G: cable holder, H: sports type of height, Kva, Kva, Kva, J: generators, K: booths, Trans. Padmounted kva:, Diesel rpm kva, Pvc pipe. Bench, Bt., cut, Pvc pipes., Primary circuit phase cable, Minced stone, Bt., At., Connector, Screw connector, Dead terminal hood insulation, Modular insertion terminal, Naked cable cu, transformer, Fuse of b.t., Naked cable cu, Grounding connectors, Naked cable cu ip, Naked cable cu, Grounding mesh, Neutral wire of secondary circuits, Anchor bolt, Sidewalk, Terminal connector, Secondary phase cable, gravel, cut, Primary circuit phase cable, Modular insertion terminal, Elbow breaker, Grounding device, sidewalk, Base for pedestal transformers with input socket, plant, Distance near objects near, Transformer base, At., Tanquilla, Bt., Kva, Pedestal type, Three-phase, Transformers, Distance near objects near, Dimensions in centimeters, D: for transformer type pedestal basement entrance
Raw text data extracted from CAD file:
Drawing labels, details, and other text information extracted from the CAD file (Translated from Spanish):
Only one per phase of the distribution type will be used., Tribution of each, To provide some service., Detail transition structure, The land drain will be made inside the post. In addition, another downpipe can be installed inside the one in which case the, The lightning rods for an underground system are of the two-phase type of the distribution type. For underground connections, Next to the post must be built a m. On the floor of the same must leave an area with gravel to, sewer system. The floor of the log should have a slope to the drain. For more details, consult, In the transition should be installed protection equipment in addition to lightning protection for surge protection account., Is called transition to the change of bare air conductor isolated conductor to interconnect with a system of underground distribution, Ground must be installed inside the log in the area for drainage. Connect the earth tube., Connector stirrup for arvidal, Awg kv power cable with display, Tubular foot post. simple, insulator, Down, Spike awg kv mca. Cat. do not., Awg semi-hard wire., Kv fuse cutouts, Autovalvular pararrayo zinc oxide kv mca. Joslyn, Galvanized metal crosspiece, Copperweld mca. Copperweld., Copperweld rod connector., Material transition, rush, To the transformer, C.f.e., Pvc, A: terna with only elementary school, Bare copper lime wire., Awg kv spike insulation, Kv autovalvular arrest, Kv fuse cut-off switch, Cup ternimal spike lime. Awg kv, Galvanized iron crosshead, Cable xple cal., Connection to the stirrup, Arg downs, B: bench-top, C: air transition with single primary line, E: base for underground air pole, F: philips type, Locking butterfly with pressure washer stainless steel nut, Stainless steel unistrut channel, Stainless steel wall mount for heavy type tray, Stainless steel omega ceiling mount, Stainless steel ceiling mount for heavy type tray, Heavy-duty fiberglass ladder type tray, Stainless steel fixing nut with washer nut, Stainless steel threaded rod, Stainless steel nut, Pressure washer, G: cable holder, H: sport type of height, Kva, Kva, Kva, J: generators, K: booths, Trans. Padmounted kva:, Diesel rpm kva, Pvc pipe. Bench, Bt., cut, Pvc pipes., Primary circuit phase cable, Minced stone, Bt., At., Connector, Screw connector, Dead terminal hood insulation, Modular insertion terminal, Naked cable cu, transformer, Fuse of b.t., Naked cable cu, Grounding connectors, Naked cable cu ip, Naked cable cu, Grounding mesh, Neutral wire of secondary circuits, Anchor bolt, Flush sidewalk, Terminal connector, Secondary phase cable, gravel, cut, Primary circuit phase cable, Modular insertion terminal, Elbow breaker, Grounding device, sidewalk, Base for pedestal transformers with input socket, plant, Minimum distance near objects, Transformer base, At., Tanquilla, Bt., Kva, Pedestal type, Three-phase, Transformers, Minimum distance near objects, Dimensions in centimeters, D: for transformer type pedestal basement entrance
Raw text data extracted from CAD file:
Language | Spanish |
Drawing Type | Detail |
Category | Water Sewage & Electricity Infrastructure |
Additional Screenshots | |
File Type | dwg |
Materials | Glass, Steel, Other |
Measurement Units | |
Footprint Area | |
Building Features | Car Parking Lot |
Tags | alta tensão, autocad, beleuchtung, DETAIL, details, détails électriques, detalhes elétrica, DWG, electrical details, electricity, elektrische details, haute tension, high tension, hochspannung, iluminação, included, kläranlage, l'éclairage, la tour, lighting, medium, poles, torre, tower, transition, treatment plant, turm, voltage |