ADVERTISEMENT

ADVERTISEMENT

Multi 665×750 4 Floors DWG Section for AutoCAD

MULTI 6.65X7.50 4 FLOORS this is a complete map contains all electrical installations as both health; structure; architecture 1-2; lightened plane; sections and elevations dwg all in one file

Drawing labels, details, and other text information extracted from the CAD file (Translated from Spanish):

proy high cabinet, counterplate, paneled and lacquered, box of bays, width, doors, high, type, wood, glass, polarized, height, sill, windows, aluminum, glass, plant-distribution, room, julson, contractors, buildings, a the main matrix, kw h, sa, b, first floor, symbol of windows, door symbol, detail of bays, width, sill, high, type, store, after store, ss hh, dining room, kitchen, bedroom, floor foundation, room, distribution: roof, roof, shoe detail, shoe box, section, reinforcement, long. desar in cm., in meetings, minimum disposition of stirrups, f’c, upper bars, lower bars, det. d in case of plant encounters, beam d, upper bar, development length, lower bar, bar, no scale, upper, lower, running foundation, concrete screed, additional stirrups, own, compacted, filled with material, irons and stirrups according to the frame of stones, should include stones, in the shoes not, details of foundation beam, cut aa, cut bb, detail of foundations, first section, third section, second section, stair detail, column table, floor, spline, steel, detail of, columns, lengths of development, for traverse bars, length, hook, detail of the reinforcement in the, column beam knot, beam stirrups, column stirrups, technical drawing :, date :, scale :, plane :, specialty :, multifamily housing, project :, owner :, location :, revised by :, …, structure, electrical installation, joists, – the quality of the reinforcement steel will not exceed what is specified for steel arn grade, – the splices d should be made only as required or allowed by the design plans, – the overlapping splices of the reinforcement in areas of stress inversion, should remain, – overlapping or welded joints should not be made in the reinforcement within an area, beam at each side., technical specifications or as authorized by the inspector., – the sites may be of different types :, shall be treated as an element in flexocompresión., – the beams that must resist earthquake forces must comply with the indicated in this, overlapping splices of corrugated bars, – the minimum length of a splice overlapped in compression shall be the length of development in, within a required length of overlap shall be used splice type c., required overlap type b splices shall be used. if more than half of the ba- is joined, strictly necessary and if less than half of the bars are spliced ​​within one length, – splices in areas of high stress should preferably be avoided, however, if they were, where is the length of the splice, and ld is the length of development in traction., – the minimum length of the overlap in the splices overlapped in traction will be in accordance with the re, package should not coincide within the same overlap length., – the bars spliced ​​by means of overlaps are contact in elements subjected to bending, no, – the overlaps of bars forming packages must be based on the required overlap length, section for the design of the longitudinal steel., splices in the reinforcement, subject to comprehension, subject to traction, splices by overlap, – unit: king kong clay bricks, girders, confinement columns, – iron joints, column As structural, shoes, technical specifications, typical detail of lightened, interior is spliced ​​on the supports, specified, increase the length of joint, b.- in case of not spliced ​​in the areas, c.- for lightened and flat beams, the steel, in the same section, indicated or with the percentages, note, values, internal reinforcement, h any, detail for cutting of rods in traction and compression, lightened: roof, main elevation, cut cc, final roof, right lateral elevation, arrives tubing, arrives tub. of drainage, inclination of slab, drain pipe, – the drainpipes and the ventilation pipes that reach the roof, shall be prolonged above the finished floor until, with special glue, special glue., – the pipes of ventilation will be pvc – sel and will be sealed, technical specifications drainage, – the drainage pipes will be filled with water, after plugging them, – the operation of each sanitary appliance will be verified, – the drainage pipes will be pvc – sap and will be sealed with, – the separation distance between the foundation axis, the following slopes :, – the drainage pipes recessed in ceiling ten -, – the register boxes will be masonry of the -, drillo and interior surfaces tarred and polished, – the vertical drain pipes will be lined, with black wire, bronze threaded register, pvc tee – salt, pipe crossing without cone

Raw text data extracted from CAD file:

Language Spanish
Drawing Type Section
Category
Additional Screenshots
File Type dwg
Materials Aluminum, Concrete, Glass, Masonry, Steel, Wood, Other
Measurement Units Metric
Footprint Area
Building Features
Tags , , , , , , , , , , , , , , , , , , , , , , , , , ,

ADVERTISEMENT

Startland Construction

Leave a Reply

ADVERTISEMENT