ADVERTISEMENT

ADVERTISEMENT

Warehouse DWG Plan for AutoCAD

Complete plans of a warehouse – Ground – Court – facade – cimentacion – structure – hydraulic systems and health

Drawing labels, details, and other text information extracted from the CAD file (Translated from Spanish):

anden, sewer, north magn, point, staircase, early childhood, preschool, bathrooms girls, bathrooms children, classroom multiple, pantry, administration, plaza, new platform, station, to touch, gutter-ditch, tank, record plane of the axes , and definitive location, with its corresponding identification, according to the first plan provided, for the response setting out, slope, plant shafts and foundations, cross-cutting to-a ‘, iveco, strator, waiting room, management, meeting room, dining room, reception, room, kitchen, bathrooms, hall, scale :, date :, projected :, plane :, observations, tunja, design :, winery, fernando páez cruz, manager :, cross-section, owner :, area load, unloading area, first floor administrative area, second floor administrative area, loaders, monitoring, metal profiles in general., the following criteria:, for visual inspection of the weld seams will be adopted, coated, in all encounters from joists, cartels, plates and, the method of manual electric welding, with electrode, accelerated curing, loading., the accelerated concrete must provide, in the low load stage, steam at atmospheric pressure, heat and humidity, or any another, set, can be used high-pressure steam curing, to accelerate the increase in strength and reduce the time of, less equal to the design strength required for the same stage, consideration, a resistance of the concrete to compression, therefore, process previously approved by the technical supervisor, empty or segregation in the mix., generalities, project name:, date:, area-region :, type of project :, South America – colombia, structural design criteria, concrete can be placed without producing anthills, the methods of compaction and manageability are such that the, these limitations can be obviated if, in the opinion of the technical, structural supervisor, as long as If these meet the requirements of the, lightweight aggregates can be used in the production of concrete, individual reinforcement or bundles of bars, the fine aggregate will consist of natural or manufactured sand, its, for both aggregates, its particles will be clean, free of , particles will be hard, compact and resistant., h. masonry, masonry unit, structure, material storage, required strength or the service conditions of the element or, the cementitious materials and the aggregates should be stored in such a way that deterioration or contamination is prevented, with corresponding evaporation of water , that could damage the, cured, to avoid excessive temperatures in the concrete or, production methods, handling, emptying, protection and, in warm weather, where temperatures are higher than the dimensions of the block will be: , glue mortar, reinforced such as: expansion joints, foreign materials, reinforcing steel, has been provided with construction joints in concrete elements, steel rods used in the construction of structures, water, Colombian standards design and construction resistant earthquake, dead load on deck :, b. design loads, include the following points :, of concrete, clean., floor live load :, dead floor load, live load on deck :, seismic coefficient :, wind load :, last load on light deck :, stairs :, dynamic pressure of wind in building:, speed of design :, importance of the building:, dynamic pressure of the wind in deck :, composition and behavior of the concrete., previous approval of the technical supervisor., the additives that are used during the construction of the work must, the preparations prior to the placement of the concrete must, preparation of the equipment and the place of placement, be able to maintain essentially the same composition, the additives used in the concrete should be subject to the, scaly particles , organic matter or other harmful substances., salts, organic materials or other substances that may be harmful, of harmful amounts of chlorides, oils, acids, alkalis, water. in the concrete mix must be clean and free, -all equipment for the mixing and transport of the concrete must be, melconstruye, responsible engineer :, requirements for warm weather, the horizontal and vertical mortar used in the masonry, not will accept cracked, fractured, cracked units, the masonry unit will be of vertical drilling bearing, standard symbology, for welded joints, grooves or edges of pieces, bevel, flared, groove, plug, fillet, back, square, flared, a weld, weld, contour, all, field, convex, flush, support, supplementary symbols of weld, reference, of the weld symbol, location of the elements, edge of the pieces, type of contour, type of finish, depth d

Raw text data extracted from CAD file:

Language Spanish
Drawing Type Plan
Category
Additional Screenshots
File Type dwg
Materials Concrete, Masonry, Plastic, Steel, Other
Measurement Units Metric
Footprint Area
Building Features A/C, Deck / Patio
Tags , , , , , , , , , , , , , , ,

ADVERTISEMENT

Leave a Reply

ADVERTISEMENT